- Remove the fan shroud, as required.
- On those engines with a separate pulley, remove the retaining bolts and
separate the pulley from the vibration damper.
- Remove the vibration damper/pulley retaining bolt from the crankshaft end.
- Using a puller, remove the damper/pulley from the crankshaft.
- Upon installation, align the key slot of the pulley hub to the crankshaft
key. Complete the assembly in the reverse order of removal. Torque the retaining
bolts to specifications.