CAUTION
Perform thermal reactor inspection only after the reactor has cooled sufficiently
to prevent the danger of being severely burned.
- Examine the reactor housing for cracks or other signs of damage.
- Remove the air supply hose from the one-way valve. Insert a screwdriver
into the valve and test the butterfly for smooth operation. Replace the valve
if necessary.
- If the valve is functioning properly, connect the hose to it.
NOTE: Remember to check the components of the air injection
system which are related to the thermal reactor.