Previous Next

REMOVAL & INSTALLATION

No. 1 Thermosensor
  1. Remove the air cleaner assembly.
  2. If necessary, remove the starter motor as detailed under Engine Electrical.
  3. Unplug the thermosensor multiconnector.
  4. Withdraw the boot from the thermosensor.
  5. Unfasten its securing nuts and remove the switch.
  6. Installation is the reverse of removal.
Control Box
1974–75 VEHICLES

WARNING
Be sure that the ignition switch is turned off to prevent damage to the control box!

  1. Working from underneath the instrument panel, locate and disconnect the control box multiconnector.
  2. Remove the screws which secure the control box.
  3. Remove the control box.
  4. Installation is performed in the reverse order of removal.
Other Components

Any of the other components used in the airflow control system are removed by unfastening their multiconnectors and removing the screws which secure them.

Previous Next