Previous Next

Pressure Cut-off Switch

Removal & Installation

To Remove:

CAUTION
Only use Motorcraft YN-12c refrigerant oil, or a suitable equivalent, to lubricate the O-ring seal.

  1. Disconnect the electrical connector.
  2. Remove the A/C pressure cut-off switch.

To Install:

CAUTION
Only use Motorcraft YN-12c refrigerant oil, or a suitable equivalent, to lubricate the O-ring seal.

  1. Install the A/C pressure cut-off switch. Tighten to 61-121 in-lb (6.8-13.6 Nm).
  2. Connect the electrical connector.

Previous Next