Disconnect the heated oxygen sensor (HO2S) electrical connector.
Use the exhaust gas oxygen sensor socket (303-476) to remove the HO2S. If needed, lubricate the HO2S with Penetrating and Lock Lubricant #E8AZ-19A501-B or an equivalent.
Apply a light coating of anti-seize lubricant to the threads of the HO2S.
To Install:
Apply a light coating of anti-seize lubricant to the threads of the HO2S.
Install the HO2S using the exhaust gas oxygen sensor socket (303-476). Torque to 34 ft-lb (46 Nm).