Low Pressure Sensor

Removal & Installation

To Remove:

NOTE: It is not necessary to discharge the refrigerant system to remove the A/C Cycling Switch.

  1. Disconnect the connector from the A/C cycling switch.
  2. Unscrew and remove the A/C cycling switch.

To Install:

NOTE: Use only O-rings that are specifically designed for use with R-134a systems.

  1. Make sure the pressure switch bore is clean.
  2. Install the A/C cycling switch.
  3. Connect the wiring to the A/C cycling switch.
  4. Check the operation of the A/C system.