  1. Disconnect the negative battery cable.
  2. Disengage the wiring harness connector from the IAT sensor.
  3. Remove the sensor from the air cleaner outlet tube.

    To install:

  4. Wipe down the IAT sensor mounting boss to clean the sensor area of all dirt and grime.
  5. Install the sensor into the air cleaner outlet tube (B Series Pick-up and Navajo) or upper intake manifold assembly securely.
  6. Attach the wiring harness connector to the IAT sensor.
  7. Connect the negative battery cable.