Previous Next

Hydraulic Control Unit (HCU)

PUMP TESTING

  1. Disconnect the HCU pump motor electrical plug.
  2. Connect a Digital Volt/Ohm Meter (DVOM) across the two pump terminals and record the reading.
  3. The reading should be between 52–68 Ohms
  4. If not, replace the pump motor.