Hydraulic Control Unit (HCU)
PUMP TESTING
Disconnect the HCU pump motor electrical plug.
Connect a Digital Volt/Ohm Meter (DVOM) across the two pump terminals and record the reading.
The reading should be between 52–68 Ohms
If not, replace the pump motor.